RS-485 Data Interface Gives Isolated, Full-Duplex Operation

Abstract: A circuit is described that provides fully isolated RS-485 full-duplex data communication with only two integrated circuits (ICs). An internal transformer-coupled isolated supply and internal optocouplers in the data path provide typical isolation to 1600Vrms for 1 minute or 2000Vram for 1 second. Data rates of 250kbaud are achieved with internally slew-rate-limited circuits or to 2.5Mbaud with non-slew-rate limited circuits, depending upon choice of available ICs.

The simple RS-485 circuit of Figure 1 provides full-duplex communications (simultaneous transmission and reception) with only two essential packages (IC2 and IC3). Its balanced and differential data lines are necessary for high-noise environments or for long-distance transmission between a computer and its peripherals. Such transmissions are difficult, if not impossible, with the single-ended circuitry of an RS-232 transceiver.

The RS-485 standard allows for bidirectional, multi-point, party-line communications, with data rates to 10M bits/second (10Mbps) and line lengths to 1200 meters. Differential transmission provides noise immunity. The circuit shown features controlled-slew-rate drivers that minimize EMI and the reflections caused by improperly terminated cables. It also enables error-free transmissions to 250kbps. To achieve data rates to 2.5Mbps, substitute a full-slew-rate MAX1480A for IC2, a MAX485 for IC3, and R2—R5 values per Table 1.

Figure 1. IC2 and IC3 provide full-duplex data communications for cable lengths as long as 1200 meters.
Figure 1. IC2 and IC3 provide full-duplex data communications for cable lengths as long as 1200 meters.

IC2 is a complete half-duplex interface that includes transceivers, optocouplers, a power driver, and a transformer. The optocouplers transmit digital signals across the internal isolation barrier, and the center-tapped transformer transmits power across the barrier from its logic (non-isolated) side to its isolated side.

IC3, powered by the isolated VCC, upgrades the half-duplex operation of IC2 to full duplex using IC2's own dedicated optocouplers. Pin 3 must be tied low to disable IC3's driver, and pin 4 should be left floating. The driver outputs for IC2 and IC3 exhibit high impedance when active-low DE is low; bringing active-low DE high enables the outputs to function as line drivers.

The isolation barrier in IC2 typically withstands 1600Vrms for one minute or 2000Vrms for one second. Any TTL/CMOS-logic family can drive the IC2 digital inputs through a series resistor. With resistive pull-ups, the receiver outputs can drive any such logic as well. IC2's isolated outputs meet all RS-485 specifications.


관련 부품  APP 2116: Jul 09, 1998
MAX1480A 완벽한 절연, RS-485/RS-422 데이터 인터페이스 전체 데이터 시트
(PDF, 2.1MB)
MAX1480B 완벽한 절연, RS-485/RS-422 데이터 인터페이스 전체 데이터 시트
(PDF, 2.1MB)
MAX1480E ±15kV ESD 보호, 절연 RS-485/RS-422 데이터 인터페이스 전체 데이터 시트
(PDF, 1.7MB)
MAX1480E ±15kV ESD 보호, 절연 RS-485/RS-422 데이터 인터페이스 전체 데이터 시트
(PDF, 1.7MB)
MAX253 절연 RS-485 인터페이스용 변압기 드라이버 전체 데이터 시트
(PDF, 832kB)
MAX483 저전력, 슬루율 제한 RS-485/RS-422 트랜시버 전체 데이터 시트
(PDF, 536kB)
무료 샘플
MAX483E ±15kV ESD 보호, 슬루율 제한, 저전력, RS-485/RS-422 트랜시버 전체 데이터 시트
(PDF, 768kB)
무료 샘플
MAX485 저전력, 슬루율 제한 RS-485/RS-422 트랜시버 전체 데이터 시트
(PDF, 536kB)
무료 샘플
MAX485E ±15kV ESD 보호, 슬루율 제한, 저전력, RS-485/RS-422 트랜시버 전체 데이터 시트
(PDF, 768kB)
무료 샘플

자동 업데이트
관심 분야의 애플리케이션 노트가 나올 때 자동으로 업데이트를 원하십니까? 그렇다면 EE-Mail™을 신청하십시오.


We Want Your Feedback!



의견을 보내주세요!
위 내용이 도움이 되셨나요?
여러분의 의견을 기다립니다 — Maxim은 보내주신 정정이나 제안사항을 반영하고 있습니다. 이 페이지를 평가하고 의견을 보내주십시오.

 

다운로드, PDF 형식다운로드, PDF 형식 (45kB)
 AN2116, AN 2116, APP2116, Appnote2116, Appnote 2116

        •         •         •     개인정보보호 정책     •     법적 고지

    Copyright © 2009 by Maxim Integrated Products