ENGLISH 简体中文 日本語 한국어  


APPLICATION NOTE  3224

IC Drives Up to Four Single-Coil Latching Relays

Abstract: Relay-driver IC allows a 3-bit parallel interface to independently open or close each of four latching relays.

Single-coil latching relays, with applications in signal routing, audio, and automotive systems, can pose a design challenge because coil current must flow in both directions through a single coil. Current flowing in one direction latches the relay in its "set" position. Current in the opposite direction latches it in the "reset" position. The relay maintains its position even when the coil current is removed. Power is saved by removing coil current after the relay latches.

In Figure 1, current flowing from pin 1 to pin 8 latches the relay in the set position, while current from pin 8 to pin 1 resets it.

Figure 1.  Current flow in a single coil latches the corresponding relay in its SET or RESET position.
Figure 1. Current flow in a single coil latches the corresponding relay in its SET or RESET position.

A simple circuit that drives up to four single-coil latching relays (Figure 2) includes a parallel-interface relay driver (U1) with open-drain outputs (Figure 3) and inductive-kickback protection. Latch any of the four relays to its set or reset position by turning on the corresponding output (OUTX). That output is selected by asserting its digital address on pins A2-A0 while active-low CS is high. Activate the output by toggling active-low CS (Figure 4).

Figure 2.  This circuit easily drives four single-coil latching relays.
Figure 2. This circuit easily drives four single-coil latching relays.

Figure 3.  U1's open-drain outputs, from Figure 2.
Figure 3. U1's open-drain outputs, from Figure 2.

Figure 4.  Interface timing for the circuit of Figure 2.
Figure 4. Interface timing for the circuit of Figure 2.

Current flows into the enabled open drain output and latches the relay to its set or reset position, according to the direction of coil current. Drive active-low RESET low to turn off all enabled open-drain outputs. Drive active-low RESET low as soon as the relays latch to ensure lowest power consumption. Observe the set/reset timing shown in Figure 4. Do not pull active-low RESET low until the required time (tSET/RESET) has elapsed. Waiting tSET/RESET after the last active-low CS toggle ensures that all selected relays will properly latch to their intended positions.

Clamping diodes on each OUTX pin catch high-voltage transients that occur when the coil current is interrupted. Those diodes (shown in Figure 2) clamp the OUTX voltage at VCC - 0.7V.


의견을 보내주세요!
위 내용이 도움이 되셨나요?
여러분의 의견을 기다립니다 — Maxim은 보내주신 정정이나 제안사항을 반영하고 있습니다. 이 페이지를 평가하고 의견을 보내주십시오.


자동 업데이트
관심있는 분야의 애플리케이션 노트가 나올 때 자동으로 업데이트 받고 싶으세요? 그렇다면 EE-Mail™을 신청하십시오.



추가 정보  APP 3224: Jun 23, 2004
MAX4821 직렬/병렬 인터페이스가 내장된 +3.3V/+5V, 8채널 캐스케이드형 릴레이 드라이버 전체 데이터 시트
(PDF, 348kB)
무료 샘플
 

다운로드, PDF 형식다운로드, PDF 형식 (51kB)
 AN3224, AN 3224, APP3224, Appnote3224, Appnote 3224



         



   Copyright © 2008 by Maxim Integrated Products, Dallas Semiconductor    법적 고지    개인정보보호 정책