Current-Limit Switch Is Digitally Programmable

Abstract: Current-limit switches are virtually ubiquitous in system controls. They provide a safe means for regulating the current delivered to a load circuit. The switches allow the load current to increase to a programmed limit but no higher. This application note illustrates the implementation of a digitally programmable current-limit switch using MAX890L a current-limited, high-side P-channel switch and MAX5160 digital potentiometer

Additional Information: Current-limit switches are virtually ubiquitous in system controls. They provide a safe means for regulating the current delivered to a load circuit. The switches allow the load current to increase to a programmed limit but no higher. Typically, the current limit is a function of the voltage across an external resistor, produced by the current from a fixed source internal to the switch IC. This voltage serves as the reference for an internal current-limiting amplifier. By replacing the resistor with a digital potentiometer, you can easily program the current limit (see the figure below). IC1 is a current-limit switch with a maximum programmable limit of 1A. The limit equals 1380/RSET, where RSET is the resistance between pins 5 and 6 of IC2. IC2 is a 50kΩ digital potentiometer whose resistance is programmable in 32 equal increments. With active-low CS held low, high-to-low transitions at active-low INC(pin 1) increments IC2's internal counter.

Figure 1. You can program a current limit to 1A in 32 equal increments by using a digital potentiometer.
Figure 1. You can program a current limit to 1A in 32 equal increments by using a digital potentiometer.

These transitions increase the resistance between W and L when U/active-low D is low and reduce it when U/active-low D is high. IC1 includes a thermal-shutdown capability that turns the load current completely off when the chip temperature exceeds 135°C. It restores the load current when the temperature cools by 10°C. If the short-circuit fault is still present, the switch cycles off and on, yielding a pulsed load current. An open-drain fault output (pin 8) switches low when the load demands current beyond the programmed limit, enabling an external system to monitor the condition of the current switch.

A similar version of this article appeared in the August 17, 2000 issue of EDN.

We Want Your Feedback!


의견을 보내주세요!
위 내용이 도움이 되셨나요?
여러분의 의견을 기다립니다 — Maxim은 보내주신 정정이나 제안사항을 반영하고 있습니다. 이 페이지를 평가하고 의견을 보내주십시오.


자동 업데이트
관심있는 분야의 애플리케이션 노트가 나올 때 자동으로 업데이트 받고 싶으세요? 그렇다면 EE-Mail™을 신청하십시오.



추가 정보  APP 298: Aug 17, 2000
MAX5160 저전력 디지털 포텐쇼미터 전체 데이터 시트
(PDF, 264kB)
무료 샘플
MAX890L 1.2A, 전류 제한, 열 셧다운 기능이 있는 하이 사이드 p채널 스위치 전체 데이터 시트
(PDF, 744kB)
무료 샘플
 

다운로드, PDF 형식다운로드, PDF 형식 (29kB)
 AN298, AN 298, APP298, Appnote298, Appnote 298


      개인정보보호 정책    법적 고지

      Copyright © 2008 by Maxim Integrated Products, Dallas Semiconductor