Simple Change Improves PFM Boost-Controller Efficiency

Abstract: Modification to the standard PFM boost-controller circuit provides a 5% efficiency improvement at medium and light loads.

A simple modification to the standard application circuit for a high-efficiency PFM boost controller (Figure 1) yields even higher efficiency. By increasing the value of RSENSE and connecting the output filter capacitor to the current-sense pin (CS) instead of ground, the circuit's current limit is made dependent on load current. The result is lower I²R loss (in the inductor, MOSFET, and output-capacitor ESR), which gives better efficiency for light-to-medium loads.

Figure 1. Connecting the COUT capacitor to CS instead of ground causes load-dependent current limiting, which reduces I2R loss.
Figure 1. Connecting the COUT capacitor to CS instead of ground causes load-dependent current limiting, which reduces I²R loss.

Connecting the filter capacitor to CS allows RSENSE to monitor the inductor current constantly-via the MOSFET during tON and via the diode and filter capacitor during tOFF. During tON, the filter-capacitor voltage drives load current in a loop (COUT/LOAD/RSENSE) that opposes the inductor current through RSENSE. In effect, the CS node subtracts load current from inductor current during this interval. Thus, as load current increases, the higher level of inductor current required to produce 100mV across RSENSE extends the ON interval and raises the current limit:

ILIM = (100mV/RSENSE) + ILOAD.

This modification does not affect the quiescent current and requires no additional circuitry, but the voltage waveform at CS couples through COUT to the output, increasing the output ripple about 100mV for light to medium loads. To obtain a lower peak current and higher efficiency for light to medium loads, the value of RSENSE should be increased as necessary to obtain the same current limit at maximum load as that provided by the standard application circuit. Figure 2 shows the effect of a load transient on the inductor current and output ripple, and Figure 3 shows efficiency gains over the standard connection.

Figure 2. An abrupt change in load current (300mA to 1A) causes changes as shown in the inductor current (top trace, 1A/div) and VOUT ripple (ac-coupled bottom trace, 100mV/div).
Figure 2. An abrupt change in load current (300mA to 1A) causes changes as shown in the inductor current (top trace, 1A/div) and VOUT ripple (ac-coupled bottom trace, 100mV/div).

Figure 3. Efficiency for the Figure 1 circuit is 4-5% better than that of a standard connection.
Figure 3. Efficiency for the Figure 1 circuit is 4-5% better than that of a standard connection.


관련 부품  APP 1054: Apr 15, 2002
MAX1771 12V 또는 전압 조정 가능, 고효율, 저 IQ, 스텝 업 DC-DC 컨트롤러 전체 데이터 시트
(PDF, 1.6MB)
무료 샘플
MAX608 5V 또는 가변출력, 저전압, 스텝 업 DC-DC 컨트롤러 전체 데이터 시트
(PDF, 152kB)
무료 샘플
MAX770 5V/12V/15V 또는 가변출력, 고효율 Low-IQ, 스텝 업 DC-DC 컨트롤러 전체 데이터 시트
(PDF, 216kB)
무료 샘플
MAX863 듀얼, 고효율, PFM, 스텝 업 DC-DC 컨트롤러 전체 데이터 시트
(PDF, 312kB)
무료 샘플

자동 업데이트
관심 분야의 애플리케이션 노트가 나올 때 자동으로 업데이트를 원하십니까? 그렇다면 EE-Mail™을 신청하십시오.


We Want Your Feedback!



의견을 보내주세요!
위 내용이 도움이 되셨나요?
여러분의 의견을 기다립니다 — Maxim은 보내주신 정정이나 제안사항을 반영하고 있습니다. 이 페이지를 평가하고 의견을 보내주십시오.

 

다운로드, PDF 형식다운로드, PDF 형식 (50kB)
 AN1054, AN 1054, APP1054, Appnote1054, Appnote 1054

        •         •         •     개인정보보호 정책     •     법적 고지

    Copyright © 2009 by Maxim Integrated Products